Directions for Use
- immerse the assembly into HumiSeal® Stripper 1063
- soak for 30-60 minutes
- brush loose material from the assembly
- clean the assembly with IPA, DI water or other qualified cleaning solution
- inspect the assembly to ensure the coating has been completely removed
- repeat the steps above if the coating is still on the assembly
- bake for a minimum of 30 minutes @ 60 – 65°C after the final cleaning process
The use of heat is not required for use with HumiSeal® Stripper 1063. A fully cured urethane coating of nominal thickness will typically dissolve readily within 30 to 60 minutes upon contact with HumiSeal® Stripper 1063. It is important to thoroughly clean the assembly after the conformal coating removal process. Following the cleaning process, the assembly should be baked to remove residual moisture for a minimum of 30 minutes at 60 – 65°C.
Handling Precautions
- Use only in well-ventilated areas.
- Protective gloves and goggles should be worn.
- In case of prolonged skin contact, wash with water.
- In case of eye contact, flush with plenty amount of water and contact physician.
- Avoid prolonged breathing of vapors.
- Unused portions of HumiSeal® products must be disposed of in compliance with all applicable environmental regulations.
- Consult the Safety Data Sheet (SDS) for more specific product information.
- Compatible HumiSeal® Coatings
|
1A27 & 1A33 Families |
- Average Wt.(lbs) /Gal @ 20°C
|
2.10 |
|
0.84 ± .01 |
- Relative Evaporating Rate (BuAc =1)
|
11.1 |
|
12 months |
|
Clear |